TY - JOUR
T1 - Phase-contrast imaging with a compact x-ray light source
T2 - System design
AU - Sung, Yongjin
AU - Gupta, Rajiv
AU - Nelson, Brandon
AU - Leng, Shuai
AU - McCollough, Cynthia H.
AU - Graves, William
N1 - Funding Information:
Dr. McCollough receives grant funding from Siemens Healthcare for work unrelated to this project. No other authors report a potential conflict of interest.
Publisher Copyright:
© 2017 Society of Photo-Optical Instrumentation Engineers (SPIE).
PY - 2017/10/1
Y1 - 2017/10/1
N2 - X-ray phase-contrast imaging (XPCI) overcomes the problem of low contrast between different soft tissues achieved in conventional x-ray imaging by introducing x-ray phase as an additional contrast mechanism. This work describes a compact x-ray light source (CXLS) and compares, via simulations, the high quality XPCI results that can be produced from this source to those produced using a microfocus x-ray source. The simulation framework is first validated using an image acquired with a microfocus-source, propagation-based XPCI (PB-XPCI) system. The phase contrast for a water sphere simulating a simple cyst submersed in muscle is evaluated and the evolution of PB-XPCI signal as the object to detector distance is increased is demonstrated. The proposed design of a PB-XPCI system using the CXLS is described and simulated images of a coronary artery compared between CXLS and microfocus source PB-XPCI systems. To generate images with similar noise levels, a microfocus source would require a 3000 times longer exposure than would the CXLS. We conclude that CXLS technology has the potential to provide high-quality XPCI in a medical environment using extremely short exposure times relative to microfocus source approaches.
AB - X-ray phase-contrast imaging (XPCI) overcomes the problem of low contrast between different soft tissues achieved in conventional x-ray imaging by introducing x-ray phase as an additional contrast mechanism. This work describes a compact x-ray light source (CXLS) and compares, via simulations, the high quality XPCI results that can be produced from this source to those produced using a microfocus x-ray source. The simulation framework is first validated using an image acquired with a microfocus-source, propagation-based XPCI (PB-XPCI) system. The phase contrast for a water sphere simulating a simple cyst submersed in muscle is evaluated and the evolution of PB-XPCI signal as the object to detector distance is increased is demonstrated. The proposed design of a PB-XPCI system using the CXLS is described and simulated images of a coronary artery compared between CXLS and microfocus source PB-XPCI systems. To generate images with similar noise levels, a microfocus source would require a 3000 times longer exposure than would the CXLS. We conclude that CXLS technology has the potential to provide high-quality XPCI in a medical environment using extremely short exposure times relative to microfocus source approaches.
KW - compact x-ray light source
KW - microfocus x-ray sources
KW - phase-contrast CT
UR - http://www.scopus.com/inward/record.url?scp=85040467983&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85040467983&partnerID=8YFLogxK
U2 - 10.1117/1.JMI.4.4.043503
DO - 10.1117/1.JMI.4.4.043503
M3 - Article
AN - SCOPUS:85040467983
SN - 2329-4302
VL - 4
JO - Journal of Medical Imaging
JF - Journal of Medical Imaging
IS - 4
M1 - 043503
ER -