Life cycle assessment and life cycle cost analysis of anion exchange and granular activated carbon systems for remediation of groundwater contaminated by per- and polyfluoroalkyl substances (PFASs)

Anderson C. Ellis, Treavor H. Boyer, Yida Fang, Charlie J. Liu, Timothy J. Strathmann

Research output: Contribution to journalArticlepeer-review

4 Scopus citations

Abstract

Anion exchange resin (AER) and granular activated carbon (GAC) have emerged as prominent technologies for treatment of waters contaminated with per- and polyfluoroalkyl substances (PFASs). This study compares the life cycle environmental impacts and life cycle costs of remediating PFAS-contaminated groundwater with these competing technologies, using field pilot data to inform model inputs. Comparative analysis indicates that AER systems employing single-use “PFAS-selective” resins have lower environmental impacts and costs than systems using regenerable resins or GAC adsorbents, supporting its use in future remediation efforts. Use of GAC operated as a single-use adsorbent led to the highest emissions as well as the highest treatment costs, with thermally-reactivated GAC proving to be less impactful than regenerable AER treatment. Sensitivity analyses highlighted the dominance of media usage rate (MUR), which is highly dependent on the selected PFAS treatment goals, to determine environmental impacts and costs over a 30-year system life cycle. Selection of very stringent changeout criteria (e.g., detection of any PFASs in effluent) significantly reduces the advantages of single-use resins. For regenerable AER, environmental impacts were dominated by management of the PFAS-contaminated brine/co-solvent waste stream used to regenerate the adsorbent, as well as the cosolvent content of the regenerant mixture and the cosolvent recovery efficiency achieved via on-site distillation. High impacts estimated for GAC adsorption, the result of high MUR relative to ion exchange media, can be significantly reduced if spent adsorbents are reused after thermal reactivation, but impacts are still greater than those predicted for single-use ion exchange systems. Findings are expected to hold across a range of diverse sites, including drinking water systems treating more dilute sources of PFAS contamination, as PFAS breakthrough was not found to be highly sensitive to sourcewater PFAS concentrations.

Original languageEnglish (US)
Article number120324
JournalWater Research
Volume243
DOIs
StatePublished - Sep 1 2023
Externally publishedYes

Keywords

  • Anion exchange resin
  • GAC
  • LCA
  • Life cycle cost
  • PFAS
  • Sustainability

ASJC Scopus subject areas

  • Environmental Engineering
  • Civil and Structural Engineering
  • Ecological Modeling
  • Water Science and Technology
  • Waste Management and Disposal
  • Pollution