TY - JOUR
T1 - MICROCOMPUTER-BASED SIGNAL PROCESSOR FOR SHORT RANGE FM RADAR.
AU - Delauder, Donald M.
AU - Balanis, Constantine A.
AU - Kazovsky, Leonid G.
PY - 1986
Y1 - 1986
N2 - The design and testing of a microcomputer-based data acquisition and range display instrument for use with FM radar systems are described. The system was particularly designed to measure targets at close range (two meters or less). The instrument has been applied to the problem of measuring the bed level within a fluidized-bed combustion chamber. Results of the experiments indicate that for monitoring static targets, an average error of 2-4% can be expected. For the more demanding case of dynamic targets, the accuracy is reduced slightly, with errors on the order of 4%; at the same time, subjectivity is significantly increased.
AB - The design and testing of a microcomputer-based data acquisition and range display instrument for use with FM radar systems are described. The system was particularly designed to measure targets at close range (two meters or less). The instrument has been applied to the problem of measuring the bed level within a fluidized-bed combustion chamber. Results of the experiments indicate that for monitoring static targets, an average error of 2-4% can be expected. For the more demanding case of dynamic targets, the accuracy is reduced slightly, with errors on the order of 4%; at the same time, subjectivity is significantly increased.
UR - http://www.scopus.com/inward/record.url?scp=0022691101&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0022691101&partnerID=8YFLogxK
U2 - 10.1109/TIM.1986.6499060
DO - 10.1109/TIM.1986.6499060
M3 - Article
AN - SCOPUS:0022691101
SN - 0018-9456
VL - IM-35
SP - 71
EP - 77
JO - IEEE Transactions on Instrumentation and Measurement
JF - IEEE Transactions on Instrumentation and Measurement
IS - 1
ER -