T1 - Cooling-aware and thermal-aware workload placement for green HPC data centers
AU - Banerjee, Ayan
AU - Mukherjee, Tridib
AU - Varsamopoulos, Georgios
AU - Gupta, Sandeep
N1 - Copyright:
Copyright 2010 Elsevier B.V., All rights reserved.
PY - 2010
Y1 - 2010
N2 - High Performance Computing (HPC) data centers are becoming increasingly dense; the associated power-density and energy consumption of their operation is increasing. Up to half of the total energy is attributed to cooling the data center; greening the data center operations to reduce both computing and cooling energy is imperative. To this effect: i) the Energy Inefficiency Ratio of SPatial job scheduling (a.k.a. job placement) algorithms, also referred as SP-EIR, is analyzed by comparing the total (computing + cooling) energy consumption incurred by the algorithms with the minimum possible energy consumption, while assuming that the job start times are already decided to meet the Service Level Agreements (SLAs); and ii) a coordinated cooling-aware job placement and cooling management algorithm, Highest Thermostat Setting (HTS), is developed. HTS is aware of dynamic behavior of the Computer Room Air Conditioner (CRAC) units and places the jobs in a way to reduce the cooling demands from the CRACs. Dynamic updates of the CRAC thermostat settings based on the cooling demands can enable a reduction in energy consumption. Simulation results based on power measurements and job traces from the ASU HPC data center show that: i) HTS reduces the SP-EIR by 15% compared to LRH, a thermal-aware spatial scheduling algorithm; and ii) in conjunction with FCFS-Backfill, HTS increases the throughput per unit energy by 6.89% and 5.56%, respectively, over LRH and MTDP (an energy-efficient spatial scheduling algorithm with server consolidation).
AB - High Performance Computing (HPC) data centers are becoming increasingly dense; the associated power-density and energy consumption of their operation is increasing. Up to half of the total energy is attributed to cooling the data center; greening the data center operations to reduce both computing and cooling energy is imperative. To this effect: i) the Energy Inefficiency Ratio of SPatial job scheduling (a.k.a. job placement) algorithms, also referred as SP-EIR, is analyzed by comparing the total (computing + cooling) energy consumption incurred by the algorithms with the minimum possible energy consumption, while assuming that the job start times are already decided to meet the Service Level Agreements (SLAs); and ii) a coordinated cooling-aware job placement and cooling management algorithm, Highest Thermostat Setting (HTS), is developed. HTS is aware of dynamic behavior of the Computer Room Air Conditioner (CRAC) units and places the jobs in a way to reduce the cooling demands from the CRACs. Dynamic updates of the CRAC thermostat settings based on the cooling demands can enable a reduction in energy consumption. Simulation results based on power measurements and job traces from the ASU HPC data center show that: i) HTS reduces the SP-EIR by 15% compared to LRH, a thermal-aware spatial scheduling algorithm; and ii) in conjunction with FCFS-Backfill, HTS increases the throughput per unit energy by 6.89% and 5.56%, respectively, over LRH and MTDP (an energy-efficient spatial scheduling algorithm with server consolidation).
UR - http://www.scopus.com/inward/record.url?scp=78449288710&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=78449288710&partnerID=8YFLogxK
U2 - 10.1109/GREENCOMP.2010.5598306
DO - 10.1109/GREENCOMP.2010.5598306
M3 - Conference contribution
AN - SCOPUS:78449288710
SN - 9781424476138
T3 - 2010 International Conference on Green Computing, Green Comp 2010
SP - 245
EP - 256
BT - 2010 International Conference on Green Computing, Green Comp 2010
T2 - 2010 International Conference on Green Computing, Green Comp 2010
Y2 - 15 August 2010 through 18 August 2010
ER -