TY - JOUR
T1 - A microscale three-dimensional model of urban outdoor thermal exposure (TUF-Pedestrian)
AU - Lachapelle, Jacob A.
AU - Krayenhoff, E. Scott
AU - Middel, Ariane
AU - Meltzer, Samuel
AU - Broadbent, Ashley M.
AU - Georgescu, Matei
N1 - Funding Information:
Model development and evaluation was funded by a Natural Sciences and Engineering Research Council of Canada Discovery Grant to ESK. The ASU-Tempe campaign was funded by US National Science Foundation Sustainability Research Network Cooperative Agreement 1444758, the Urban Water Innovation Network.
Publisher Copyright:
© 2022, The Author(s) under exclusive licence to International Society of Biometeorology.
PY - 2022/4
Y1 - 2022/4
N2 - Urban street design choices relating to tree planting, building height and spacing, ground cover, and building façade properties impact outdoor thermal exposure. However, existing tools to simulate heat exposure have limitations with regard to optimization of street design for pedestrian cooling. A microscale three-dimensional (3D) urban radiation and energy balance model, Temperatures of Urban Facets for Pedestrians (TUF-Pedestrian), was developed to simulate pedestrian radiation exposure and study heat-reducing interventions such as urban tree planting and modifications to building and paving materials. TUF-Pedestrian simulates the spatial distribution of radiation and surface temperature impacts of trees and buildings on their surroundings at the sub-facet scale. In addition, radiation absorption by a three-dimensional pedestrian is considered, permitting calculation of a summary metric of human radiation exposure: the mean radiant temperature (TMRT). TUF-Pedestrian is evaluated against a unique 24-h observational dataset acquired using a mobile human-biometeorological station, MaRTy, in an urban canyon with trees on the Arizona State University Tempe campus (USA). Model evaluation demonstrates that TUF-Pedestrian accurately simulates both incoming directional radiative fluxes and TMRT in an urban environment with and without tree cover. Model sensitivity simulations demonstrate how modelled TMRT and directional radiative fluxes respond to increased building height (ΔTMRT reaching -32 °C when pedestrian becomes shaded), added tree cover (ΔTMRT approaching -20 °C for 8 m trees with leaf area density of 0.5 m2 m−3), and increased street albedo (ΔTMRT reaching + 6 °C for a 0.21 increase in pavement albedo). Sensitivity results agree with findings from previous studies and demonstrate the potential utility of TUF-Pedestrian as a tool to optimize street design for pedestrian heat exposure reduction.
AB - Urban street design choices relating to tree planting, building height and spacing, ground cover, and building façade properties impact outdoor thermal exposure. However, existing tools to simulate heat exposure have limitations with regard to optimization of street design for pedestrian cooling. A microscale three-dimensional (3D) urban radiation and energy balance model, Temperatures of Urban Facets for Pedestrians (TUF-Pedestrian), was developed to simulate pedestrian radiation exposure and study heat-reducing interventions such as urban tree planting and modifications to building and paving materials. TUF-Pedestrian simulates the spatial distribution of radiation and surface temperature impacts of trees and buildings on their surroundings at the sub-facet scale. In addition, radiation absorption by a three-dimensional pedestrian is considered, permitting calculation of a summary metric of human radiation exposure: the mean radiant temperature (TMRT). TUF-Pedestrian is evaluated against a unique 24-h observational dataset acquired using a mobile human-biometeorological station, MaRTy, in an urban canyon with trees on the Arizona State University Tempe campus (USA). Model evaluation demonstrates that TUF-Pedestrian accurately simulates both incoming directional radiative fluxes and TMRT in an urban environment with and without tree cover. Model sensitivity simulations demonstrate how modelled TMRT and directional radiative fluxes respond to increased building height (ΔTMRT reaching -32 °C when pedestrian becomes shaded), added tree cover (ΔTMRT approaching -20 °C for 8 m trees with leaf area density of 0.5 m2 m−3), and increased street albedo (ΔTMRT reaching + 6 °C for a 0.21 increase in pavement albedo). Sensitivity results agree with findings from previous studies and demonstrate the potential utility of TUF-Pedestrian as a tool to optimize street design for pedestrian heat exposure reduction.
KW - Human biometeorology
KW - Mean radiant temperature
KW - Numerical modelling
KW - Simulation
KW - Street trees
KW - Thermal comfort
KW - Urban climate
UR - http://www.scopus.com/inward/record.url?scp=85124238734&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85124238734&partnerID=8YFLogxK
U2 - 10.1007/s00484-022-02241-1
DO - 10.1007/s00484-022-02241-1
M3 - Article
C2 - 35118573
AN - SCOPUS:85124238734
SN - 0020-7128
VL - 66
SP - 833
EP - 848
JO - International journal of biometeorology
JF - International journal of biometeorology
IS - 4
ER -